.. Class Doc file class cobra.model.eqpt.IngrDropPkts1d ===================================== .. class:: cobra.model.eqpt.IngrDropPkts1d A class that represents the most current statistics for ingress drop packets in a 1 day sampling interval. This class updates every hour. Containers: * :class:`cobra.model.pc.AggrIf` * :class:`cobra.model.l1.PhysIf` Properties: - bufferAvg : Ingress buffer drop packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferBase : Ingress buffer drop packets. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferCum : Ingress buffer drop packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferLast : Ingress buffer drop packets. This is the most current value read by the counter. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferMax : Ingress buffer drop packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferMin : Ingress buffer drop packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferPer : Ingress buffer drop packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferRate : Ingress buffer drop packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferSpct : Ingress buffer drop packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferThr : Ingress buffer drop packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferTr : Ingress buffer drop packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - bufferTrBase : Ingress buffer drop packets. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - childAction : Delete or ignore. For internal use only. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: True - cnt : The number of readings made within the current sample. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: True - dn : A tag or metadata is a non-hierarchical keyword or term assigned to the fabric module. + isNaming: False + isCreateOnly: True + isConfig: False + isImplicit: True - errorAvg : Ingress error drop packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorBase : Ingress error drop packets. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorCum : Ingress error drop packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorLast : Ingress error drop packets. This is the most current value read by the counter. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorMax : Ingress error drop packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorMin : Ingress error drop packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorPer : Ingress error drop packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorRate : Ingress error drop packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorSpct : Ingress error drop packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorThr : Ingress error drop packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorTr : Ingress error drop packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - errorTrBase : Ingress error drop packets. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingAvg : Ingress forwarding drop packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingBase : Ingress forwarding drop packets. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingCum : Ingress forwarding drop packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingLast : Ingress forwarding drop packets. This is the most current value read by the counter. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingMax : Ingress forwarding drop packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingMin : Ingress forwarding drop packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingPer : Ingress forwarding drop packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingRate : Ingress forwarding drop packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingSpct : Ingress forwarding drop packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingThr : Ingress forwarding drop packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingTr : Ingress forwarding drop packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - forwardingTrBase : Ingress forwarding drop packets. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lastCollOffset : The start date and time of the statistical data sample. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: True - lbAvg : Ingress load balancer drop packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbBase : Ingress load balancer drop packets. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbCum : Ingress load balancer drop packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbLast : Ingress load balancer drop packets. This is the most current value read by the counter. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbMax : Ingress load balancer drop packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbMin : Ingress load balancer drop packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbPer : Ingress load balancer drop packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbRate : Ingress load balancer drop packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbSpct : Ingress load balancer drop packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbThr : Ingress load balancer drop packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbTr : Ingress load balancer drop packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - lbTrBase : Ingress load balancer drop packets. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: False - modTs : The modification time stamp. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: True - repIntvEnd : + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: True - repIntvStart : The length of time (seconds) for the statistical data sample. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: True - rn : Identifies an object from its siblings within the context of its parent object. The distinguished name contains a sequence of relative names. + isNaming: False + isCreateOnly: True + isConfig: False + isImplicit: True - status : The upgrade status. This property is for internal use only. + isNaming: False + isCreateOnly: False + isConfig: False + isImplicit: True