class cobra.model.comp.RcvdPkts5min¶
-
class
cobra.model.comp.
RcvdPkts5min
¶
A class that represents the most current statistics for received packets in a 5 minute sampling interval. This class updates every 10 seconds.
Containers:
- Properties:
bcastAvg : Received broadcast packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastBase : Received broadcast packets. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastCum : Received broadcast packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastLast : Received broadcast packets. This is the most current value read by the counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastMax : Received broadcast packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastMin : Received broadcast packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastPer : Received broadcast packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastRate : Received broadcast packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastSpct : Received broadcast packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastThr : Received broadcast packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastTr : Received broadcast packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bcastTrBase : Received broadcast packets. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
childAction : Delete or ignore. For internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
cnt : The number of readings made within the current sample.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
dn : A tag or metadata is a non-hierarchical keyword or term assigned to the fabric module.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
lastCollOffset :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
mcastAvg : Received multicast packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastBase : Received multicast packets. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastCum : Received multicast packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastLast : Received multicast packets. This is the most current value read by the counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastMax : Received multicast packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastMin : Specifies the minimum read value of the multicast packets counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastPer : Specifies the periodic value of the multicast packets counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastRate : Received multicast packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastSpct : Specifies the number of missing or incorrect readings of the multicast packets counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastThr : Specifies the threshold crossing flags of the multicast packets counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastTr : Specifies the trend of the multicast packets counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
mcastTrBase : Received multicast packets. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
modTs : The time when this object was last modified.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
repIntvEnd :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
repIntvStart :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
rn : Identifies an object from its siblings within the context of its parent object. The distinguished name contains a sequence of relative names.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
status : The upgrade status. This property is for internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
totalAvg : Received packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalBase : Received packets. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalCum : Received packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalLast : Received packets. This is the most current value read by the counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalMax : Received packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalMin : Received packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalPer : Received packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalRate : Received packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalSpct : Received packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalThr : Received packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalTr : Received packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalTrBase : Received packets. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False