class cobra.model.eqpt.EgrTotal1year¶
-
class
cobra.model.eqpt.
EgrTotal1year
¶
A class that represents the most current statistics for egress in a 1 year sampling interval. This class updates every day.
- Containers:
- Properties:
bytesAvg : Total egress bytes. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesBase : Total egress bytes. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesCum : Total egress bytes. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesLast : Total egress bytes. This is the most current value read by the counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesMax : Total egress bytes. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesMin : Total egress bytes. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesPer : Total egress bytes. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRate : Total egress bytes. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateAvg : Total egress bytes rate. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateLast : Total egress bytes rate. This is the most current value read by the counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateMax : Total egress bytes rate. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateMin : Total egress bytes rate. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateSpct : Total egress bytes rate. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateThr : Total egress bytes rate. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateTr : Total egress bytes rate. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateTrBase : Total egress bytes rate. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesRateTtl : Total egress bytes rate. This is the total sum of all values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesSpct : Total egress bytes. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesThr : Total egress bytes. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesTr : Total egress bytes. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
bytesTrBase : Total egress bytes. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
childAction : Delete or ignore. For internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
cnt : The number of readings made within the current sample.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
dn : A tag or metadata is a non-hierarchical keyword or term assigned to the fabric module.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
lastCollOffset : The start date and time of the statistical data sample.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
modTs : The modification time stamp.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
pktsAvg : Total egress packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsBase : Total egress packets. This is the cumulative value of the counter after the last reset of the hardware counter. Note that this value continues through each interval without resetting to zero. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsCum : Total egress packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsLast : Total egress packets. This is the most current value read by the counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsMax : Total egress packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsMin : Total egress packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsPer : Total egress packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRate : Total egress packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateAvg : Total egress packets rate. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateLast : Total egress packets rate. This is the most current value read by the counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateMax : Total egress packets rate. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateMin : Total egress packets rate. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateSpct : Total egress packets rate. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateThr : Total egress packets rate. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateTr : Total egress packets rate. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateTrBase : Total egress packets rate. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsRateTtl : Total egress packets rate. This is the total sum of all values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsSpct : Total egress packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsThr : Total egress packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsTr : Total egress packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
pktsTrBase : Total egress packets. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
repIntvEnd :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
repIntvStart : The length of time (seconds) for the statistical data sample.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
rn : Identifies an object from its siblings within the context of its parent object. The distinguished name contains a sequence of relative names.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
status : The upgrade status. This property is for internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
utilAvg : Egress link utilization. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
utilLast : Egress link utilization. This is the most current value read by the counter.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
utilMax : Egress link utilization. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
utilMin : Egress link utilization. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
utilSpct : Egress link utilization. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
utilThr : Egress link utilization. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
utilTr : Egress link utilization. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
utilTrBase : Egress link utilization. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
utilTtl : Egress link utilization. This is the total sum of all values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False