class cobra.model.eqptcapacity.BDEntry1w¶
-
class
cobra.model.eqptcapacity.
BDEntry1w
¶
A class that represents the most current statistics for bridge domain entry in a 1 week sampling interval. This class updates every day.
- Containers:
- Properties:
childAction : Delete or ignore. For internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
cnt : The number of readings made within the current sample.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
dn : A tag or metadata is a non-hierarchical keyword or term assigned to the fabric module.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
lastCollOffset :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
modTs : The time when this object was last modified.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
normalizedAvg : The normalized temperature average. Temperature readings are normalized to a 0-100 scale. The normal operation temperature of a component can be 35-65 degrees. A value of 42 would be normalized to (42-35)*100/(65-35). This is necessary to present a uniform picture for various components that have different operating thresholds.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
normalizedLast : The last normalized reading. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
normalizedMax : The largest normalized temperature average. Temperature readings are normalized to a 0-100 scale. The normal operation temperature of a component can be 35-65 degrees. A value of 42 would be normalized to (42-35)*100/(65-35). This is necessary to present a uniform picture for various components that have different operating thresholds. This value is only overwritten if the most current value is greater than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 5, the previous value is overwritten with 5. If the third reading is smaller than 5, the value remains at 5. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
normalizedMin : The lowest normalized temperature average. Temperature readings are normalized to a 0-100 scale. The normal operation temperature of a component can be 35-65 degrees. A value of 42 would be normalized to (42-35)*100/(65-35). This is necessary to present a uniform picture for various components that have different operating thresholds. This value is only overwritten if the most current value is less than the previous value. For example, if the value of the first reading is 5 and the value of the second reading is 3, the previous value is overwritten with 3. If the third reading is greater than 3, the value remains at 3. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
normalizedSpct : The missed and/or incorrect normalized temperature average readings. Temperature readings are normalized to a 0-100 scale. The normal operation temperature of a component can be 35-65 degrees. A value of 42 would be normalized to (42-35)*100/(65-35). This is necessary to present a uniform picture for various components that have different operating thresholds.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
normalizedThr : The threshold crossing flags of the normalized temperature average. Temperature readings are normalized to a 0-100 scale. The normal operation temperature of a component can be 35-65 degrees. A value of 42 would be normalized to (42-35)*100/(65-35). This is necessary to present a uniform picture for various components that have different operating thresholds. The threshold crossing flags indicate the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
normalizedTr : The trending value of the normalized temperature average. Temperature readings are normalized to a 0-100 scale. The normal operation temperature of a component can be 35-65 degrees. A value of 42 would be normalized to (42-35)*100/(65-35). This is necessary to present a uniform picture for various components that have different operating thresholds. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
normalizedTrBase : The cumulative value of the normalized calculation from the previous interval. This value does not reset.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
normalizedTtl : The total sum of all values read for specifying the normalized calculation. This value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
repIntvEnd :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
repIntvStart :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
rn : Identifies an object from its siblings within the context of its parent object. The distinguished name contains a sequence of relative names.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
status : The upgrade status. This property is for internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True