class cobra.model.l2.IngrPktsPartHist1d¶
-
class
cobra.model.l2.
IngrPktsPartHist1d
¶
A class that represents historical portion of the statistics for ingress packets in a 1 day sampling interval. This class updates every hour.
- Containers:
cobra.model.vns.EPpInfo
cobra.model.vns.SDEPpInfo
cobra.model.fv.InBEpP
cobra.model.fv.RtdEpP
cobra.model.dhcp.PRelPg
cobra.model.fv.BrEpP
cobra.model.fv.AEPg
cobra.model.l2ext.InstP
cobra.model.vns.SHEPpInfo
cobra.model.l3ext.InstP
cobra.model.infra.PEPg
cobra.model.fv.InstPEpP
cobra.model.fv.OoBEpP
cobra.model.infra.CEPg
cobra.model.vns.REPpInfo
cobra.model.fv.SvcBD
cobra.model.mgmt.InB
cobra.model.fv.SvcEpP
cobra.model.fv.EpP
cobra.model.fv.BD
cobra.model.fv.Ctx
cobra.model.dhcp.CRelPg
cobra.model.l3ext.InstPDef
- Properties:
childAction : Delete or ignore. For internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
cnt : The number of readings made within the current sample.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
dn : A tag or metadata is a non-hierarchical keyword or term assigned to the fabric module.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
dropAvg : Ingress drop packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
dropCum : Ingress drop packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
dropMax : Ingress drop packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
dropMin : Ingress drop packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
dropPer : Ingress drop packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
dropRate : Ingress drop packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
dropSpct : Ingress drop packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
dropThr : Ingress drop packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
dropTr : Ingress drop packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodAvg : Ingress flood packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodCum : Ingress flood packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodMax : Ingress flood packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodMin : Ingress flood packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodPer : Ingress flood packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodRate : Ingress flood packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodSpct : Ingress flood packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodThr : Ingress flood packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
floodTr : Ingress flood packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
index :
- isNaming: True
- isCreateOnly: True
- isConfig: True
- isImplicit: False
lastCollOffset :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
modTs : The time when this object was last modified.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
multicastAvg : Ingress multicast packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
multicastCum : Ingress multicast packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
multicastMax : Ingress multicast packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
multicastMin : Ingress multicast packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
multicastPer : Ingress multicast packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
multicastRate : Ingress multicast packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
multicastSpct : Ingress multicast packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
multicastThr : Ingress multicast packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
multicastTr : Ingress multicast packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
nodeId : The ID of the APIC, leaf, or spine from which the core file was uploaded.
- isNaming: True
- isCreateOnly: True
- isConfig: True
- isImplicit: False
repIntvEnd :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
repIntvStart :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
rn : Identifies an object from its siblings within the context of its parent object. The distinguished name contains a sequence of relative names.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
status : The upgrade status. This property is for internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
unicastAvg : Ingress unicast packets. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
unicastCum : Ingress unicast packets. The total sum of the values read. Note that this value continues through each interval without resetting to zero.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
unicastMax : Ingress unicast packets. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
unicastMin : Ingress unicast packets. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
unicastPer : Ingress unicast packets. The total sum of the values read during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
unicastRate : Ingress unicast packets. This is the rate of the counter during the collection interval. The rate is calculated by dividing the periodic value by the length of the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
unicastSpct : Ingress unicast packets. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
unicastThr : Ingress unicast packets. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
unicastTr : Ingress unicast packets. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False