class cobra.model.proc.SysLoad1d

class cobra.model.proc.SysLoad1d

A class that represents the most current statistics for system load in a 1 day sampling interval. This class updates every hour.

Containers:
Properties:
  • childAction : Delete or ignore. For internal use only.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: True
  • cnt : The number of readings made within the current sample.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: True
  • dn : A tag or metadata is a non-hierarchical keyword or term assigned to the fabric module.

    • isNaming: False
    • isCreateOnly: True
    • isConfig: False
    • isImplicit: True
  • lastCollOffset :

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: True
  • loadAverage15mAvg : 15 minute average load. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage15mLast : 15 minute average load. This is the most current value read by the counter.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage15mMax : 15 minute average load. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage15mMin : 15 minute average load. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage15mSpct : 15 minute average load. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage15mThr : 15 minute average load. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage15mTr : 15 minute average load. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage15mTrBase : 15 minute average load. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage15mTtl : 15 minute average load. This is the total sum of all values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mAvg : 1 minute average load. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mLast : 1 minute average load. This is the most current value read by the counter.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mMax : 1 minute average load. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mMin : 1 minute average load. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mSpct : 1 minute average load. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mThr : 1 minute average load. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mTr : 1 minute average load. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mTrBase : 1 minute average load. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage1mTtl : 1 minute average load. This is the total sum of all values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mAvg : 5 minute average load. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mLast : 5 minute average load. This is the most current value read by the counter.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mMax : 5 minute average load. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mMin : 5 minute average load. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mSpct : 5 minute average load. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mThr : 5 minute average load. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mTr : 5 minute average load. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mTrBase : 5 minute average load. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • loadAverage5mTtl : 5 minute average load. This is the total sum of all values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • modTs : The time when this object was last modified.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: True
  • repIntvEnd :

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: True
  • repIntvStart :

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: True
  • rn : Identifies an object from its siblings within the context of its parent object. The distinguished name contains a sequence of relative names.

    • isNaming: False
    • isCreateOnly: True
    • isConfig: False
    • isImplicit: True
  • runProcAvg : Running processes. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • runProcLast : Running processes. This is the most current value read by the counter.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • runProcMax : Running processes. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • runProcMin : Running processes. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • runProcSpct : Running processes. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • runProcThr : Running processes. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • runProcTr : Running processes. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • runProcTrBase : Running processes. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • runProcTtl : Running processes. This is the total sum of all values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • status : The upgrade status. This property is for internal use only.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: True
  • totalProcAvg : Total processes. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • totalProcLast : Total processes. This is the most current value read by the counter.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • totalProcMax : Total processes. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • totalProcMin : Total processes. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • totalProcSpct : Total processes. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • totalProcThr : Total processes. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • totalProcTr : Total processes. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • totalProcTrBase : Total processes. This is the cumulative value of the counter from the previous collection interval. Used for internal purposes.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False
  • totalProcTtl : Total processes. This is the total sum of all values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.

    • isNaming: False
    • isCreateOnly: False
    • isConfig: False
    • isImplicit: False