class cobra.model.proc.SysLoadHist1w¶
-
class
cobra.model.proc.
SysLoadHist1w
¶
A class that represents historical statistics for system load in a 1 week sampling interval. This class updates every day.
- Containers:
- Properties:
childAction : Delete or ignore. For internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
cnt : The number of readings made within the current sample.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
dn : A tag or metadata is a non-hierarchical keyword or term assigned to the fabric module.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
index :
- isNaming: True
- isCreateOnly: True
- isConfig: True
- isImplicit: False
lastCollOffset :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
loadAverage15mAvg : 15 minute average load. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage15mMax : 15 minute average load. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage15mMin : 15 minute average load. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage15mSpct : 15 minute average load. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage15mThr : 15 minute average load. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage15mTr : 15 minute average load. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage1mAvg : 1 minute average load. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage1mMax : 1 minute average load. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage1mMin : 1 minute average load. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage1mSpct : 1 minute average load. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage1mThr : 1 minute average load. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage1mTr : 1 minute average load. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage5mAvg : 5 minute average load. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage5mMax : 5 minute average load. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage5mMin : 5 minute average load. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage5mSpct : 5 minute average load. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage5mThr : 5 minute average load. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
loadAverage5mTr : 5 minute average load. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
modTs : The time when this object was last modified.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
repIntvEnd :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
repIntvStart :
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
rn : Identifies an object from its siblings within the context of its parent object. The distinguished name contains a sequence of relative names.
- isNaming: False
- isCreateOnly: True
- isConfig: False
- isImplicit: True
runProcAvg : Running processes. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
runProcMax : Running processes. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
runProcMin : Running processes. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
runProcSpct : Running processes. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
runProcThr : Running processes. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
runProcTr : Running processes. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
status : The upgrade status. This property is for internal use only.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: True
totalProcAvg : Total processes. This is the average value read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalProcMax : Total processes. This is the largest value read by the counter during the collection interval. This value is only overwritten if the most current value is larger than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 4, the previous value is overwritten with 4. If the third reading is smaller than 4, the value remains at 4. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalProcMin : Total processes. This is the smallest value read by the counter during the collection interval. This value is only overwritten if the most current value is smaller than the previous value. For example, if the value of the first reading is 3 and the value of the second reading is 2, the previous value is overwritten with 2. If the third reading is larger than 2, the value remains at 2. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalProcSpct : Total processes. This is the number of missed and/or incorrect values read by the counter during the collection interval. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalProcThr : Total processes. This indicates the properties of the counter that crossed the threshold during the collection interval. Note that this value resets at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False
totalProcTr : Total processes. This is the trending value of the counter. Note that this value resets to 0 at the beginning of each interval.
- isNaming: False
- isCreateOnly: False
- isConfig: False
- isImplicit: False